R# | Site | Serial Number | Measurement | Start Date | Start Time | End Date | End Time | Data Quality Statement |
1 | BMS | | Diffuse CM22 (unit 2) | 04/21/2024 | 00:00:00 | 04/21/2024 | 23:59:00 | Tracker arm on one side of tracker was bumped out of position that caused Diffuse CM22-2 and SR25 to become unshaded. However data was substituted with the CM22-1. |
2 | BMS | | Diffuse CM22 (unit 2) | 04/08/2024 | 10:50:00 | 04/08/2024 | 11:25:00 | Cable was snagged on tracker that caused Diffuse CM22-2 and SR25 to become unshaded. However data was substituted with the CM22-1. |
3 | BMS | | Diffuse CM22 (unit 2) | 02/11/2024 | 06:01:00 | 02/11/2024 | 13:27:00 | Snow was built-up around the pyranometer dome creating very high diffuse irradiance. However data was substituded with the CM22-1 which was free of snow. |
4 | BMS | | Diffuse CM22 (unit 2) | 09/29/2023 | 12:40:00 | 09/29/2023 | 13:55:00 | Due to an NREL-wide power outage caused by Xcel Energy, The following BMS instruments were not pointing at the sun during this time: Direct CHP-1, sNIP, CUVA2, CUVB2, TUVR; and the following instruments were un-shaded: Diffuse 8-48, CM22-2, PIR. CM22 Data was corrected on 10/5/2023 by subsituting Diffuse with calibrated RSR Diffuse (calibrated by BMS for the 2 hours prior), then re-calculating Direct using BMS Global CMP22 and calibrated RSR Diffuse. |
5 | BMS | | Diffuse CM22 (unit 2) | 08/22/2023 | 13:24:00 | 08/22/2023 | 15:46:00 | Due to BMS south sci-tec failure, The following BMS instruments were not pointing at the sun during this time: Direct CHP-1, sNIP, MS-57, CUVA2, CUVB2, TUVR; and the following instruments were un-shaded: Diffuse 8-48, CM22-2, PIR. However automatic substitution was enabled for the CHP1-1, sNIP, 8-48, and CM22-2. |
6 | BMS | | Diffuse CM22 (unit 2) | 08/21/2022 | 05:21:00 | 08/21/2022 | 11:15:00 | Due to BMS south sci-tec failure, The following BMS instruments were not pointing at the sun during this time: Direct CHP-1, sNIP, CUVA2, CUVB2, TUVR; and the following instruments were un-shaded: Diffuse 8-48, CM22-2, PIR. Since the middle sci-tec was down (due to collision with south scitec); data was corrected on 9/14/2022 by subsituting Diffuse 8-48 and CM22-2 with RSR Diffuse, then recalating Direct CHP1-1 and sNIP using BMS Global CMP22 and RSR Diffuse. |
7 | BMS | | Diffuse CM22 (unit 2) | 08/20/2022 | 11:56:00 | 08/20/2022 | 23:59:00 | Due to BMS south sci-tec failure, The following BMS instruments were not pointing at the sun during this time: Direct CHP-1, sNIP, CUVA2, CUVB2, TUVR; and the following instruments were un-shaded: Diffuse 8-48, CM22-2, PIR. However automatic substitution was enabled for the CHP1-1, 8-48, and CM22-2. |
8 | BMS | | Diffuse CM22 (unit 2) | 06/22/2022 | 16:53:00 | 06/23/2022 | 07:17:00 | Due to BMS south sci-tec failure, The following BMS instruments were not pointing at the sun during this time: Direct CHP-1, sNIP, CUVA2, CUVB2, TUVR; and the following instruments were un-shaded: Diffuse 8-48, CM22-2, PIR. However automatic data substitution was enable for the CHP1-1, 8-48, and CM22-2. |
9 | BMS | | Diffuse CM22 (unit 2) | 06/18/2020 | 07:11:00 | 12/15/2021 | 19:31:00 | DATA CORRECTED on 12/17/2021: Irradiances were increased by 0.675% due to revised BORCAL report for all BMS shortwave radiometers calibrated in 2020 and 2021. |